Schlumberger Data file dictionary for Northern Newark Basin - Tandem Lot 1

tandem1_ait-1m-ac.dat = Array Induction Imager Tool - After Coring - Run 1 - Main Pass
tandem1_ait-1m.dat = Array Induction Imager Tool - Run 1 - Main Pass
tandem1_ait-1r-ac.dat = Array Induction Imager Tool - After Coring - Run 1 - Repeat Pass
tandem1_ait-1r.dat = Array Induction Imager Tool - Run 1 - Repeat Pass
tandem1_ait-2m.dat = Array Induction Imager Tool - Run 2 - Main Pass
tandem1_ait-2r.dat = Array Induction Imager Tool - Run 2 - Repeat Pass
tandem1_cali-tld-1m.dat = Caliper - Three Detector Density Tool - Run 1 - Main Pass
tandem1_cali-tld-1r.dat = Caliper - Three Detector Density Tool - Run 1 - Repeat Pass
tandem1_cali-tld-2m.dat = Caliper - Three Detector Density Tool - Run 2 - Main Pass
tandem1_cali-tld-2r.dat = Caliper - Three Detector Density Tool - Run 2 - Repeat Pass
tandem1_cbl-1d.dat = Casing Bond Log - Run 1 - Downlog
tandem1_cbl-1m.dat = Casing Bond Log - Run 1 - Main Pass
tandem1_cbl-1r.dat = Casing Bond Log - Run 1 - Repeat Pass
tandem1_cbl-2m.dat = Casing Bond Log - Run 2 - Main Pass
tandem1_cbl-2r.dat = Casing Bond Log - Run 2 - Repeat Pass
tandem1_cmr-1m-t2dist.dat = NMR T2 Distribution - Combinable Magnetic Resonance Tool - Run 1 - Main Pass
tandem1_cmr-1m.dat = Combinable Magnetic Resonance Tool - Run 1 - Main Pass
tandem1_cmr-1r-t2dist.dat = NMR T2 Distribution - Combinable Magnetic Resonance Tool - Run 1 - Repeat Pass
tandem1_cmr-1r.dat = Combinable Magnetic Resonance Tool - Run 1 - Repeat Pass
tandem1_cmr-2m-t2dist.dat = NMR T2 Distribution - Combinable Magnetic Resonance Tool - Run 2 - Main Pass
tandem1_cmr-2m.dat = Combinable Magnetic Resonance Tool - Run 2 - Main Pass
tandem1_cmr-2r-t2dist.dat = NMR T2 Distribution - Combinable Magnetic Resonance Tool - Run 2 - Repeat Pass
tandem1_cmr-2r.dat = Combinable Magnetic Resonance Tool - Run 2 - Repeat Pass
tandem1_ecs-1m-capt-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 1 - Main Pass
tandem1_ecs-1m-inel-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 1 - Main Pass
tandem1_ecs-1r-capt-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 1 - Repeat Pass
tandem1_ecs-1r-inel-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 1 - Repeat Pass
tandem1_ecs-2m-capt-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 2 - Main Pass
tandem1_ecs-2m-elements.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 2 - Main Pass
tandem1_ecs-2m-inel-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 2 - Main Pass
tandem1_ecs-2m-minerals.dat = Elemental Capture Spectroscopy Sonde - Run 2 - Main Pass
tandem1_ecs-2r-capt-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 2 - Repeat Pass
tandem1_ecs-2r-inel-yields.dat = Elemental Yields - Elemental Capture Spectroscopy Sonde - Run 2 - Repeat Pass
tandem1_edtc-ait-1m-ac.dat = Enhanced Digital Telemetry Cartridge - Array Induction Imager Tool String - After Coring - Run 1 - Main Pass
tandem1_edtc-ait-1m.dat = Enhanced Digital Telemetry Cartridge - Array Induction Imager Tool String - Run 1 - Main Pass
tandem1_edtc-ait-1r.dat = Enhanced Digital Telemetry Cartridge - Array Induction Imager Tool String - Run 1 - Repeat Pass
tandem1_edtc-cmr-1m.dat = Enhanced Digital Telemetry Cartridge - Combinable Magnetic Resonance Tool String - Run 1 - Main Pass
tandem1_edtc-cmr-1r.dat = Enhanced Digital Telemetry Cartridge - Combinable Magnetic Resonance Tool String - Run 1 - Repeat Pass
tandem1_edtc-cmr-2m.dat = Enhanced Digital Telemetry Cartridge - Combinable Magnetic Resonance Tool String - Run 2 - Main Pass
tandem1_edtc-cmr-2r.dat = Enhanced Digital Telemetry Cartridge - Combinable Magnetic Resonance Tool String - Run 2 - Repeat Pass
tandem1_edtc-fmi-11-ac.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 1
tandem1_edtc-fmi-12-ac.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 2
tandem1_edtc-fmi-1m.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - Run 1 - Main Pass
tandem1_edtc-fmi-1r.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - Run 1 - Repeat Pass
tandem1_edtc-fmi-2-ac.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - After Coring - Pass 2
tandem1_edtc-fmi-2ml.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Lower Section
tandem1_edtc-fmi-2mu.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Upper Section
tandem1_edtc-fmi-2r.dat = Enhanced Digital Telemetry Cartridge - Fullbore Formation MicroImager Tool String - Run 2 - Repeat Pass
tandem1_edtc-usit-2m-csg.dat = Enhanced Digital Telemetry Cartridge - Ultrasonic Imaging Tool String - Through Casing - Run 2 - Main Pass
tandem1_edtc-usit-2r-csg.dat = Enhanced Digital Telemetry Cartridge - Ultrasonic Imaging Tool String - Through Casing - Run 2 - Repeat Pass
tandem1_gr-hgns-ait-1m.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 1 - Main Pass
tandem1_gr-hgns-ait-1r.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 1 - Repeat Pass
tandem1_gr-hgns-ait-2m.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 2 - Main Pass
tandem1_gr-hgns-ait-2r.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 2 - Repeat Pass
tandem1_gr-hgns-cmr-1m.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Combinable Magnetic Resonance Tool String - Run 1 - Main Pass
tandem1_gr-hgns-cmr-1r.dat = Gamma Ray - Highly Integrated Gamma Ray Neutron Sonde - Combinable Magnetic Resonance Tool String - Run 1 - Repeat Pass
tandem1_hngs-cmr-2m.dat = Hostile Environment Gamma Ray Sonde - Combinable Magnetic Resonance Tool String - Run 2 - Main Pass
tandem1_hngs-cmr-2r.dat = Hostile Environment Gamma Ray Sonde - Combinable Magnetic Resonance Tool String - Run 2 - Repeat Pass
tandem1_hngs-fmi-11-ac.dat = Hostile Environment Gamma Ray Sonde - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 1
tandem1_hngs-fmi-12-ac.dat = Hostile Environment Gamma Ray Sonde - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 2
tandem1_misc-ait-1m-ac.dat = Miscellaneous Measurements - Array Induction Imager Tool String - After Coring - Run 1 - Main Pass
tandem1_misc-ait-1m.dat = Miscellaneous Measurements - Array Induction Imager Tool String - Run 1 - Main Pass
tandem1_misc-ait-1r-ac.dat = Miscellaneous Measurements - Array Induction Imager Tool String - After Coring - Run 1 - Repeat Pass
tandem1_misc-ait-1r.dat = Miscellaneous Measurements - Array Induction Imager Tool String - Run 1 - Repeat Pass
tandem1_misc-ait-2m.dat = Miscellaneous Measurements - Array Induction Imager Tool String - Run 2 - Main Pass
tandem1_misc-ait-2r.dat = Miscellaneous Measurements - Array Induction Imager Tool String - Run 2 - Repeat Pass
tandem1_misc-cmr-1m.dat = Miscellaneous Measurements - Combinable Magnetic Resonance Tool String - Run 1 - Main Pass
tandem1_misc-cmr-1r.dat = Miscellaneous Measurements - Combinable Magnetic Resonance Tool String - Run 1 - Repeat Pass
tandem1_misc-cmr-2m.dat = Miscellaneous Measurements - Combinable Magnetic Resonance Tool String - Run 2 - Main Pass
tandem1_misc-cmr-2r.dat = Miscellaneous Measurements - Combinable Magnetic Resonance Tool String - Run 2 - Repeat Pass
tandem1_misc-fmi-11-ac.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 1
tandem1_misc-fmi-12-ac.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - After Coring - Run 1 -Pass 2
tandem1_misc-fmi-1m.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - Run 1 - Main Pass
tandem1_misc-fmi-1r.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - Run 1 - Repeat Pass
tandem1_misc-fmi-2-ac.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - After Coring - Pass 2
tandem1_misc-fmi-2ml.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Lower Section
tandem1_misc-fmi-2mu.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Upper Section
tandem1_misc-fmi-2r.dat = Miscellaneous Measurements - Fullbore Formation MicroImager Tool String - Run 2 - Repeat Pass
tandem1_misc-usit-1d-csg.dat = Miscellaneous Measurements - Ultrasonic Imaging Tool String - Through Casing - Run 1 - Downlog
tandem1_misc-usit-1m-csg.dat = Miscellaneous Measurements - Ultrasonic Imaging Tool String - Through Casing - Run 1 - Main Pass
tandem1_misc-usit-1r-csg.dat = Miscellaneous Measurements - Ultrasonic Imaging Tool String - Through Casing - Run 1 - Repeat Pass
tandem1_misc-usit-2m-csg.dat = Miscellaneous Measurements - Ultrasonic Imaging Tool String - Through Casing - Run 2 - Main Pass
tandem1_misc-usit-2r-csg.dat = Miscellaneous Measurements - Ultrasonic Imaging Tool String - Through Casing - Run 2 - Repeat Pass
tandem1_por-hgns-ait-1m.dat = Porosity - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 1 - Main Pass
tandem1_por-hgns-ait-1r.dat = Porosity - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 1 - Repeat Pass
tandem1_por-hgns-ait-2m.dat = Porosity - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 2 - Main Pass
tandem1_por-hgns-ait-2r.dat = Porosity - Highly Integrated Gamma Ray Neutron Sonde - Array Induction Imager Tool String - Run 2 - Repeat Pass
tandem1_ppc-cmr-1m.dat = Power Positioning Device and Caliper Tool - Combinable Magnetic Resonance Tool String - Run 1 - Main Pass
tandem1_ppc-cmr-1r.dat = Power Positioning Device and Caliper Tool - Combinable Magnetic Resonance Tool String - Run 1 - Repeat Pass
tandem1_ppc-fmi-1m.dat = Power Positioning Device and Caliper Tool - Fullbore Formation MicroImager Tool String - Run 1 - Main Pass
tandem1_ppc-fmi-1r.dat = Power Positioning Device and Caliper Tool - Fullbore Formation MicroImager Tool String - Run 1 - Repeat Pass
tandem1_ppc-fmi-2ml.dat = Power Positioning Device and Caliper Tool - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Lower Section
tandem1_ppc-fmi-2mu.dat = Power Positioning Device and Caliper Tool - Fullbore Formation MicroImager Tool String - Run 2 - Main Pass - Upper Section
tandem1_ppc-fmi-2r.dat = Power Positioning Device and Caliper Tool - Fullbore Formation MicroImager Tool String - Run 2 - Repeat Pass
tandem1_sp-1m-ac.dat = Spontaneous Potential Log - After Coring - Run 1 - Main Pass
tandem1_sp-1m.dat = Spontaneous Potential Log - Run 1 - Main Pass
tandem1_sp-1r-ac.dat = Spontaneous Potential Log - After Coring - Run 1 - Repeat Pass
tandem1_sp-1r.dat = Spontaneous Potential Log - Run 1 - Repeat Pass
tandem1_sp-2m.dat = Spontaneous Potential Log - Run 2 - Main Pass
tandem1_sp-2r.dat = Spontaneous Potential Log - Run 2 - Repeat Pass
tandem1_sscanner-1m.dat = Sonic Scanner - Run 1 - Main Pass
tandem1_sscanner-1r.dat = Sonic Scanner - Run 1 - Repeat Pass
tandem1_sscanner-2ml.dat = Sonic Scanner - Run 2 - Main Pass - Lower Section
tandem1_sscanner-2mu.dat = Sonic Scanner - Run 2 - Main Pass - Upper Section
tandem1_sscanner-2r.dat = Sonic Scanner - Run 2 - Repeat Pass
tandem1_tld-1m.dat = Three Detector Density Tool - Run 1 - Main Pass
tandem1_tld-1r.dat = Three Detector Density Tool - Run 1 - Repeat Pass
tandem1_tld-2m.dat = Three Detector Density Tool - Run 2 - Main Pass
tandem1_tld-2r.dat = Three Detector Density Tool - Run 2 - Repeat Pass