Wireline Temperature Data Processing

 

ODP logging contractor: LDEO-BRG

Well name: 765D

Leg: 123

Location: Argo Abyssal Plain (SE Indian Ocean)

Latitude: 15° 58.54' N

Longitude: 117° 34.49' E

Logging date: October, 1988

Bottom felt: 5724.3 mbrf

Total penetration: 1194.9 mbsf

Total core recovered: 78.7 m ( %)

 

Water Depth: 5713.5 mbsl

Temperature Tool Used: LDEO-TLT

Depth versus time recording available: NO

Logging Runs

 

Logging string 1: DIT/SDT/NGT

Logging string 2: LDT/CNT/NGT

Wireline heave compensator was used to counter ship heave.

Hole 765C was drilled with the following deviation from the vertical:

4 ° at 400 m (deviated)

6.6 ° at 580 m (deviated)

10 ° at 777 m (deviated).

No correction has been performed for the deviation.

 

Tool Information

 

The LDEO-TLT tool is a self-contained, high precision, low-temperature logging tool that is attached to the bottom of the Schlumberger tool strings. The tool provides two temperature measurements (in degree Celsius, recorded by a fast-response and a slow-response thermistor.  The fast-response thermistor, though low in accuracy, is able to detect sudden, small temperature excursions caused by fluid flow between the formation and the borehole. The highly accurate, slow-response thermistor can be used to estimate heat flow. Pressure and the two temperature measurements are recorded as a function of time: conversion to depth can be based on the pressure reading (Legs 123-157) or, preferably, on simultaneous recording (by Schlumberger) of depth and time (Legs 159-181).

 

Data Processing

 

A linear relationship of pressure versus depth has been calculated from the pressure reading at the mudline and at the total logging depth for each logging run. The pressure at the mudline corresponds to the pressure recorded by the tool during the calibration stop (about 5 minutes), which takes place at the mudline on each logging run. The pressure readings are then converted to depth using a pressure/depth conversion that is linearly interpolated between the values determined at the mudline and total logging depth.

 

Depth = Pressure * x - WD

 

where

 

Depth = mbsf

Pressure = bars

x = pressure conversion coefficient (m/bars)

WD = mbsl

 

This procedure does not fully account for the vagaries of the pressure readings that result in lots of ups and downs in the generated depth channel. Further problems arise because of pumping during logging operations, which affects the pressure, especially when the Side Entry Sub is used. Also, whenever heavy pills of mud are used, the pressure-depth calculation is affected, resulting in a non-linear effect that is difficult to account for. If the pressure conversion coefficient is recalculated for the mudline, the resultant total depth is often wrong.

 

The following processing has been performed at Hole 765C:

 

Logging Run: DIT/SDT/NGT

Mudline (?) P=580 bars at 6845 sec

x=WD/580=9.847

Pmax=638 bars at 10073 sec

Pressure conversion factor calculated from pressure at mudline

Depth=Pressure * 9.847-5717.7

 

Information about the temperature logging operations can be found in the Site Chapter (Operations, Downhole Measurements, and Heat Flow sections), ODP IR volume 123.

 

Cristina Broglia
Phone: 845-365-8343
Fax: 845-365-3182
E-mail: Cristina Broglia